Fitting Remington Model 504 Extractors
Not all gun parts, right out of the package, are ready for functional installation. The Model 504 Remington is no exception.
In working with three Remington Model 504 target rifles, all showed a defect in cartridge extraction. This was particularly true when attempting to extract unfired cartridges from a Bentz match chamber where the bullet would engage the rifling leade. Extraction was sometimes a problem with full velocity loads where the fired cartridge would fully obturate the chamber and cling more tightly to the chamber wall.
The underlying problem was in the hook effect of the extractor, apart which is located on the right side of the bolt. .22 rimfire bolts are often described as having two extractors, though this is not the case. The extractor is positioned on the right side of the bolt and extracts the cartridge case, whereas the laterally-opposing, similar-looking part on the opposite side of the bolt is the ejector. It serves two purposes.
First, it holds and helps in aligning the cartridge as it is picked up from the magazine and cams over the case rim when a cartridge is loaded as a single shot. Its secondary purpose is to hold the cartridge, loaded or fired, in alignment with the bolt face as the bolt is withdrawn until the case contacts the ejector lip. At this stage of extraction and ejection, the left side of the case rim bumps the extractor lip and jumps off the ejector, throwing it out to the right.
Both the extractor and ejector have Extractor and ejector are both recessed into the back of the barrel for case chambering, extraction and ejection. The bolt (left) shows the ejector on the left side and extractor at right. Bolt head at right shows extractor at left and ejector at right. angled noses and are spring loaded within a slot and hole in the bolt. Understanding the function of these two little parts is the key to understanding malfunction causes and their correction.
Extractor Hook Angle Problem A close inspection of the Model 504 Remington extractor showed the hook angle to be too open, causing the hook to slip off the case rim during extraction, sometimes leaving the case in the chamber. The secondary contributing cause for failure to extract was too weak an extractor
spring, which allowed the case rim to slip off the extractor too freely as the case was partially extracted. Solution And Testing Two basically simple remedies were applied in correcting the problem. The extractor is easily removed by simply swinging it outward from the main axis of the bolt. A spring and plunger hold it in position. Caution must be exercised to not lose this tiny part or the spring and plunger.
Carefully examination of the extractor hook showed a slight angle away from square, which will cause Along with increased spring pressure these measures solved erratic extraction problems. Below center: Top side view of the Model 504 Remington bolt. Extractors are shown at right on each bolt with the more rounded nose of the ejectors on the left side. The improved hook angle of the extractor is shown here. The improved hook effect on the extractors is clearly shown here. it to slip off the case rim.
I used a small machinist file to correct this angle. Be sure not to remove metal from the very tip of the extractor as the angle is being re-formed. After changing the extractor hook angle I replaced the existing spring with a stronger one, which was also a bit longer. The parts were tested for function by chambering and extracting actual live rounds as the gun barrel was directed at a safe backstop. This was done from the magazine and single loading.
I then fired several live rounds using both match Far The case is held by the extractor (left) and the ejector (right.) Note the more beveled lip of the ejector on right and more pointed lip of the extractor on left. Metal is removed up to the broken line, as shown in photo, thereby improving extraction. Extractor is shown below, hooked onto rim of .22 long rifle cartridge. ammunition as well as higher velocity loads. In all cases extraction was without flaw.
Conclusions It is not infrequent for a very small gun part to cause a big problem. Where extraction failure is the case, it must be solved. Sometimes small changes solve the problem as we saw here with the Model 504 Remington. Sometimes we must dig deeper. AG
Continue reading
More from the archive
More from this issue
Industry Research
The National Shooting Sports Foundation (NSSF) has been supplying the firearms and ammunition industry with a variety of research reports and data on industry indicators for nearly 10 years. Each year, NSSF builds upon past research and fulfills member requests for information…
Precision Barrel Fitting, Part Seven
In this part we’ll dive deeper into possible problems faced in chambering and how to avoid them.
The Right Tools Are Not Enough
Why gunsmiths need to regularly calibrate their measurement tools.
Ruger Mark II Pistol
Maintaining the target quality Ruger Mark II, with thoughts on the Standard, Mark III and 22/45 models.
More from this author
New Tools For Old Hunting Arms
There are many good reasons why hunters use non-modern hunting arms. Here are two examples from custom builds of a customer’s crossbow and muzzleloader.
Bluing Browning Shotguns
Prepping and cold bluing a neglected Browning shotgun.
Modifying Gun Screws
How to modify a screw to fit your project’s needs.
Case Turning Fixture
How to make a cartridge case turning fixture.
Related workshop reading
Beretta Cheetah Model 84
work on one demonstrates key points common to them all.
The Model 71 Winchester
A history and notes on the Model 71 Winchester, a classic American lever action rifle.
Reader Forum
Winchester 94 Issue I have a late Winchester Model 94 End of Trail chambered in 357 Magnum that has feeding issues. The link is apparently worn and will not always prevent cartridges in the magazine tube from dumping under the carrier, locking…
Making Springs
A how to on making V-springs in your shop.
MFGAxis Discussion